What to Consider When Choosing a Data Center
Data center selection guide: Tier classification, power redundancy, cooling systems, physical security, network connectivity and SLA guarantees. TIER 3 data center in Turkey.
Table of Contents
What to Consider When Choosing a Data Center
Data center selection directly determines the reliability and performance of your server infrastructure. A wrong data center choice can lead to unexpected outages, data loss, and business continuity issues. This guide explains all the critical factors to consider when choosing a data center.
Tier Classification
The Uptime Institute classifies data centers into four Tier levels. This classification determines the reliability and uptime guarantee of the data center.
Tier 1 — Basic Infrastructure
Tier 1 Features:
- Annual uptime: 99.671%
- Annual downtime: 28.8 hours
- Power: Single path
- Cooling: Single path
- Maintenance: Requires downtime
- Use: Small businesses, test environments
Tier 2 — Redundant Components
Tier 2 Features:
- Annual uptime: 99.741%
- Annual downtime: 22 hours
- Power: N+1 redundant
- Cooling: N+1 redundant
- Maintenance: Partial downtime required
- Use: Medium-sized businesses
Tier 3 — Concurrent Maintenance
Tier 3 Features:
- Annual uptime: 99.982%
- Annual downtime: 1.6 hours
- Power: N+1 or 2N redundant
- Cooling: N+1 redundant
- Maintenance: Can be done without downtime
- Use: Enterprise applications, e-commerce
Tier 4 — Full Fault Tolerance
Tier 4 Features:
- Annual uptime: 99.995%
- Annual downtime: 26.3 minutes
- Power: 2N+1 fully redundant
- Cooling: 2N fully redundant
- Maintenance: Completely uninterrupted
- Use: Critical infrastructure, finance, healthcare
Tier Comparison Table
| Feature | Tier 1 | Tier 2 | Tier 3 | Tier 4 |
|---|---|---|---|---|
| Annual Uptime | 99.671% | 99.741% | 99.982% | 99.995% |
| Annual Downtime | 28.8 hrs | 22 hrs | 1.6 hrs | 26 min |
| Power Paths | 1 | 1+backup | 2 | 2+backup |
| Cooling | Single | N+1 | N+1 | 2N |
| Maintenance | Disruptive | Partial | Non-disruptive | Non-disruptive |
Minimum Tier 3 is recommended for enterprise use. Tier 3 means only ~1.6 hours of downtime per year and is sufficient for most businesses.
Power Infrastructure
Power Redundancy Levels
N → Single power source (minimum)
N+1 → One backup power source
2N → Double copy of everything
2N+1 → Double copy + extra backup
UPS (Uninterruptible Power Supply)
UPS ensures servers continue to operate during grid outages.
Things to Check:
- Is UPS capacity sufficient?
- Battery age and maintenance status
- Automatic transfer time
- Is bypass mode available?
Generator
Generator Features:
- Fuel type: Diesel (preferred)
- Startup time: < 30 seconds
- Fuel capacity: How many hours?
- Automatic fuel replenishment agreement?
- Test frequency: Monthly testing?
Cooling Systems
Servers generate a lot of heat. Insufficient cooling leads to hardware failures and shortened lifespan.
PUE (Power Usage Effectiveness)
PUE = Total Facility Power / IT Equipment Power
PUE Assessment:
1.0: Excellent (theoretical minimum)
1.2: Very good
1.5: Good
2.0: Average
> 2.0: Inefficient
Hot/Cold Aisle Separation
Cold Aisle: Front of servers (air intake)
Hot Aisle: Back of servers (air exhaust)
Benefits:
- Prevents mixing of cold and hot air
- Increases cooling efficiency
- Saves energy
Physical Security
Access Control
Security Layers:
1. Perimeter security (fence, camera)
2. Building entrance (security personnel)
3. Data center entrance (card reader)
4. Rack room entrance (biometric)
5. Individual rack lock
Mantrap (Double Door System)
Mantrap Operation:
1. Person enters outer door
2. Outer door closes
3. Authentication is performed
4. If approved, inner door opens
Advantage: Prevents unauthorized entry
Network Connectivity
BGP and Multiple Upstream
Single Upstream (Bad):
Data Center → ISP A → Internet
Risk: If ISP A fails, all connectivity is lost
Multiple Upstream (Good):
Data Center → ISP A → Internet
→ ISP B → Internet
→ ISP C → Internet
Automatic load balancing and failover with BGP
Internet Exchange (IX) Connectivity
IX points are where different networks connect directly to each other. IX connectivity provides:
- Lower latency
- Better route diversity
- Lower transit cost
- Local traffic optimization
SLA and Compensation Policy
SLA Evaluation Criteria
SLA Checklist:
✓ What is the uptime guarantee? (99.9%, 99.99%?)
✓ How is downtime measured?
✓ Is planned maintenance included in SLA?
✓ What is the compensation rate?
✓ Is compensation automatic or does it require a request?
✓ What is the maximum compensation amount?
✓ What is the notification period?
REXE's TIER 3 Istanbul Data Center
REXE Technology serves from a TIER 3 certified data center in Istanbul.
REXE Data Center Features:
Tier Certification:
- TIER 3 certified
- 99.982% uptime SLA
- ~1.6 hours maximum downtime per year
Power Infrastructure:
- N+1 UPS system
- Diesel generator (72+ hours of fuel)
- Automatic transfer switch
Cooling:
- N+1 CRAC units
- Hot/cold aisle separation
- PUE < 1.5
Physical Security:
- 24/7 security personnel
- Biometric access control
- CCTV system
- Mantrap entry
Network Connectivity:
- Multiple upstream via Path.net
- Turkey IX connectivity
- BGP routing
- Tbps-capacity DDoS protection
Don't just look at price when choosing a data center. Tier certification, power redundancy, and network connectivity quality are much more important in the long run. REXE's TIER 3 infrastructure provides enterprise-level reliability.
Related Articles
REXE Service Comparison: VDS, Dedicated, Colocation Guide
Compare REXE Technology's VDS, dedicated server, colocation, and rack rental services in detail. Find the right hosting solution for your needs with our pricing and feature guide.
Server Backup Options and Data Recovery Guide for REXE
REXE Technology backup options: automatic snapshots, manual backups, and application-level backup strategies. Learn how to prevent data loss and recover quickly from any incident.
SLA and Uptime Guarantee: REXE 99.9% Service Commitment
REXE Technology SLA policy: 99.9% uptime guarantee, credit policy, uptime calculation and data center infrastructure. Learn your rights and the credit process during outages.